Search

Show simple item record

dc.contributorБрестский государственный технический университетru_RU
dc.contributorBrest State Technical Universityru_RU
dc.contributor.authorКузавков, Василий Викторович
dc.contributor.authorЧетверкина, Галина Андреевна
dc.coverage.spatialБрестru_RU
dc.date.accessioned2019-08-21T12:20:20Z
dc.date.available2019-08-21T12:20:20Z
dc.date.issued2014
dc.identifier.citationКузавков, В. В. Построение проверочных тестов диагностирования радиоэлектронных компонентов для бесконтактного индукционного метода / В. В. Кузавков, Г. А. Четверкина // Вестник Брестского государственного технического университета. Серия: Физика, математика, информатика. – 2014. – №5. – С. 67–70.ru_RU
dc.identifier.urihttps://rep.bstu.by/handle/data/914
dc.descriptionKUZAVKOV W.V., CHETVIORKINA G.A. Building a screening test diagnosis radio-electronic components for contactless inductive methodru_RU
dc.description.abstractВ работе определен общий подход к построению функциональных проверяющих тестов для бесконтактного индукционного метода диагностирования радиоэлектронных компонентов. В качестве радиоэлектронных компонентов рассмотрены цифровые логические элементы.ru_RU
dc.language.isoruru_RU
dc.publisherБрГТУru_RU
dc.relation.ispartofseriesФизика, математика, информатика;
dc.subjectмеханикаru_RU
dc.subjectmechanicsru_RU
dc.titleПостроение проверочных тестов диагностирования радиоэлектронных компонентов для бесконтактного индукционного методаru_RU
dc.typeСтатья (Article)ru_RU
dc.identifier.udc681.35ru_RU
dc.abstract.alternativeThe structure of modern electronic technology facilities include digital blocks, which consist of radio-electronic components (REC). Conducting quality control of the technical state of the digital REC depends on the method of diagnosis. A promising method of diagnosing REC is a non-contact induction method of diagnosis. Summary contactless inductive method (hereinafter - method) diagnosing digital blocks is that the parameters are used as a diagnostic signal parameters, which are induced at the terminals of the conductive parts of the measuring coil from a test unit to a digital signal. Under the current carrying element is understood the power cord digital unit (positive or cabinet). The work is accompanied by a digital unit change in the magnetic field around the wire supply feeding a diagnostic test. Is input REC test sequence xi triggers the element, respectively, with sales in its function. When this occurs on a SDS corresponding sequence of signals (feedback) ӯк.i . If the input sequence contains xi a functional screening test, the total response of the rivers can be represented as a sequence of response elements on FPT ӯфпт.i and redundant sets ӯнд.i . This total response ӯк.i.ет has reference to the case of a fully serviceable REC.ru_RU


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record